Pressure impulse (Short term/Long term)
According to the standard: According to customers requirements, reference standard: TL 82472-2014 5.3, 4.1&4.3 leakage test is carried out to generate positive/negative pressure alternating curve after cycle completion.
Environment condition: Temperature: 18~28℃; Humidity: 25~75%RH.
Technical requirements:
1. Test temperature: 120 ° C
2. Test pressure: Pu=-0.85 bar, Po=Pmax × 1.27 (Pmax=1.5 bar)
3. Test gas temperature: 120 ° C
4. Cycle times: 200,000 times
5. Test frequency: 0.833Hz
6. Determine requirements: Leakage ≤ 15ml / min, No deformation allowed, record installation and disassembly torque.