Test parameters and methods
1. Test parameters
A. Test medium: Ester 7131
B. Temperature of medium: -25℃≤Tf≤105℃
C. Pressure of coolant: -0.2bar<p<3.5bar
D. Periodic pressure cycle times: 100,000
E. Circulating pressure cycle schematic diagram:
2. Test methods
Install the oil radiator on the test bench, start the hydraulic system, and adjust according to the requirements of the given technical parameters. During the test, observe whether the oil radiator leaks or deforms.