1. Specification and model: SL-TCX-SS
2. According to the standard:
GB 6952-2015 Sanitary wares 1. Toilets
3. Test items:
Test of transportation characteristics of 18m horizontal pipe in drainage pipe.
4. Technical parameters
Static pressure: 0.04~0.8Mpa, accuracy: Level 0.5 (using sanitary flushing function)
Dynamic pressure: 0.04~0.6 Mpa, accuracy: Level 0.5 (using sanitary flushing function)
Test piece range: According to the standard GB 6952-2015 Sanitary wares
18m pipe drainage pipe transportation characteristic station: length×width×height=20000×500×800mm
18m pipe drainage pipe transportation characteristics:
Working conditions: Temperature 5°C-40°C, humidity≤95%
18m pipe transportation device:
Drainage pipe length: A total of 18 meters, marked for every 3 meters
Drainage pipe downstream slope: 0.020
Drainage pipe diameter: Inner diameter 100mm
Vertical distance between the installation platform of the toilet and the elbow center of the 18m transportation drainage pipe: 200mm
There is a 38mm diameter opening at the 3m position of the drainage pipe